Computational Storage Market Size, Share & Trends Analysis Report By Product Type (Computational Storage Drive, Computational Storage Processor, Computational Storage Array), By Application (Data Compression & Deduplication, Database & Analytics Acceleration, Encryption & Data Protection, AI Inference & Vector Search, Media Processing & Others), By Region, And Segment Forecasts, 2026 - 2035 : Transparent compression carries current volume while a ratified command set and thin application support set the pace for programmable offload
The global Computational Storage market was valued at USD 714.8 Million in 2025 and is projected to reach USD 6,551.3 Million by 2035, registering a CAGR of 24.8% during the forecast period. The market revenue growth is mainly supported by inline compression on enterprise drives, by the movement of filtering and data preparation work closer to stored data in AI inference pipelines, and by the arrival of a ratified command set that lets a host invoke a program on a device without vendor-specific code. Computational storage is a storage device or adapter that performs work on the data it holds instead of returning every byte to the server processor. SNIA defines three device classes. A computational storage drive combines persistent storage with one or more compute elements. A computational storage processor supplies compute to an associated storage system but holds no persistent data of its own. A computational storage array places compute elements at the array level, behind array control software. This report values those devices and adapters at product price, and it covers only equipment that executes work on the data path. Conventional enterprise solid state drives are treated in the Nodvolt Enterprise SSD report, the controller silicon inside them in the SSD Controller report, and network offload adapters in the DPU and SmartNIC reports, so none of that value is counted here.
Revenue in 2025 came almost entirely from one function. Transparent compression, which the drive performs with no change to the application above it, is the only computational storage feature shipping in enterprise volume, and it is sold as an attribute of a drive rather than as a separate product. DapuStor lists the function across its enterprise range alongside flexible data placement and fault prediction, and the Chinese cloud operators that buy those drives treat it as a capacity measure rather than as a compute feature. Everything that requires the host to load and then call a program remains in qualification or in pilot deployment. The standards position did improve during the year. SNIA adopted version 1.1 of its Computational Storage Architecture and Programming Model as a technical position on 31 May 2025, which fixed the definitions of the three device classes and the mechanism a host uses to discover compute elements. Adoption has not followed the specification work. Revenue remains small in absolute terms after more than a decade of product announcements, and two of the three device classes defined in the model have no product behind them shipping at scale.
Two conditions shape 2026 and 2027. The first is the completion of the host interface. NVM Express published the NVMe 2.4 specification set on 4 August 2026, which carries the Computational Programs Command Set and the Subsystem Local Memory Command Set alongside the base and NVM command sets. A drive can now expose a program, and a host can allocate memory on the device and call that program, using commands defined outside any single vendor's driver. Silicon and firmware supporting those commands reach qualification during 2027, so the revenue effect falls into the later part of the forecast. The second condition is the cost of the underlying drive, which the U.S.-Iran conflict has raised. The IMF put the March 2026 position plainly: with the Strait of Hormuz shut, close to 20% of world oil supply and of seaborne liquefied natural gas cargoes could not be reached. Flash wafers, controller die and drive assembly are concentrated in Japan, South Korea, China and Taiwan, and all four import most of their energy. A computational storage drive carries a price premium over a plain drive of the same capacity, and that premium is the first item a buyer reconsiders when the base drive itself becomes more expensive.
The computational element in a computational storage drive sits beside the flash controller and takes one of two forms. The first is a set of fixed-function blocks, placed either on the controller die itself or on a companion device. These include a compression engine implementing GZIP, LZ4 or Zstandard, an AES engine for encryption at rest, a Reed-Solomon unit that generates erasure-coding parity, and a scan unit that applies a comparison to records as they stream off the NAND channels. Such blocks are small, they run at NAND bandwidth and they add little die area, which is why compression and encryption reached volume before anything else. The second form is an embedded processor complex, usually several Arm application cores with private DRAM, running a small operating system that hosts a program supplied by the customer. Programmable elements are also built on adaptive system-on-chip and field-programmable gate array devices from AMD, Altera and Achronix. That route is taken when the offloaded function changes faster than a mask set can be respun. Each form returns host cycles to the application. Eideticom states that its cryptographic offload cuts host processor use by up to 96% and power consumption by 43%. A database filter pays the same dividend in a different currency, because a predicate applied at the drive returns matching records instead of whole blocks. The energy case rests on the same arithmetic. Moving a word out of DRAM into a processor register costs one to two orders of magnitude more energy than the arithmetic performed on it, and moving it across PCIe from a drive costs more again. A function that touches every byte once and discards most of what it reads is therefore cheaper to run where the bytes already sit.
The three device classes differ in where that element sits, and the difference decides who can buy them. A computational storage drive holds the compute and the flash in one package, so the offload scales with the number of drives and consumes no additional slot. A computational storage processor holds compute without persistent storage, usually as a PCIe card, and serves a group of ordinary drives. That spreads one accelerator across a shelf and suits a fleet already qualified on standard media. A computational storage array places the function in the array controller, where erasure coding, compression and inference data preparation are applied across every device behind it. Software decides which of the three a buyer can actually use. SNIA publishes a Computational Storage API alongside its architecture model, and NVM Express has now defined the wire commands, but an offload only earns its price when an unmodified filesystem, database or inference framework can reach it. That is the test this market has failed for a decade, and it is also why compression succeeded, since compression requires no call at all. The last test is arithmetic. An embedded Arm core on a drive runs at a lower clock and a narrower issue width than a server core, and a data processing unit on the same PCIe root complex can compress or encrypt for many drives from one engine. Per-drive silicon therefore has to win on the bytes it never moves rather than on the operations it performs. That limits the viable offload set to functions that are bandwidth-bound, parallel across devices, and applied to data the host would otherwise have to read in full.
The table below maps the value chain for computational storage, from the flash die through the controller and the compute element to the host command set, the system software and the installed array, with the suppliers active at each level and the timing of each step.
| Level | Technology | Function | Active suppliers | Timing |
|---|---|---|---|---|
| Flash die and array | 3D NAND in triple-level and quad-level cell form | Holds the data that the computation reads without it leaving the drive | Kioxia, Samsung Electronics, SK hynix, Micron Technology, Sandisk | In volume; layer counts above 300 in production |
| Flash controller | Multi-channel NVMe controller on a logic process with a low-density parity-check decoder | Schedules NAND access, corrects bit errors and presents the NVMe namespace | Marvell Technology, ScaleFlux, Silicon Motion, Phison Electronics, in-house designs at the flash producers | In volume |
| Compute element on the drive | Fixed-function compression, AES and erasure-coding blocks; embedded Arm cores with private DRAM | Executes the offloaded function on data already inside the device | ScaleFlux, DapuStor, Samsung Electronics, Kioxia | Compression in volume; programmable elements in qualification |
| Accelerator card without storage | Adaptive system-on-chip and field-programmable gate array devices with hard PCIe blocks | Serves a shelf of ordinary drives from one engine, and can be reprogrammed after deployment | Eideticom, NETINT Technologies, Pliops, Advanced Micro Devices, Altera | Shipping into selected accounts |
| Host interface and command set | PCIe Gen5; NVMe Computational Programs and Subsystem Local Memory command sets | Lets a host discover, load, and invoke a program and allocate memory on the device | NVM Express, SNIA, PCI-SIG | NVMe 2.4 set published August 2026; silicon from 2027 |
| System software | SNIA Computational Storage API, filesystem and database integration, vector database and inference framework plug-ins | Determines whether an unmodified application can reach the offload at all | SNIA, Linux kernel maintainers, database and AI framework projects | Partial; the main constraint on adoption |
| Array and end platform | All-flash and disaggregated storage systems with compute in the array controller | Applies erasure coding, compression and inference data preparation across every device behind the controller | Everpure, VAST Data, DDN, IBM, Dell Technologies | In volume at array level |
Rising use of vector search and retrieval in production inference is another major factor supporting market growth. A vector index over a large corpus does not fit in server DRAM at a sensible cost, so the index is placed on flash and read during each query. Kioxia released its AiSAQ vector search library as open source in January 2025, specifically so that index data could be held on solid state drives rather than in DRAM. The same pattern applies to the key-value cache that an inference server keeps between turns of a conversation. Cache that exceeds accelerator memory is written to flash and read back, and the read path benefits from filtering and decompression performed before the data crosses PCIe. Storage vendors have begun to sell this as an array function rather than as a drive feature. Everpure, the storage vendor formerly named Pure Storage, announced a design win with a second top-five hyperscaler in August 2026. Demand of this kind is new, and it is the part of the market least dependent on the standards work that has held back programmable offload.
In addition, the same work can be performed by hardware the buyer already owns. Server processors now carry built-in compression and encryption accelerators. A data processing unit placed on the same PCIe root complex can serve an entire shelf of ordinary drives from one engine. Graphics processors are faster still for the index and embedding work on which the AI case depends. Kioxia reported in March 2026 that it had built a database of 4.8 billion high-dimensional vectors on a single server, with index build time cut by a factor of 7.8 through the use of GPUs. Each of these alternatives removes a reason to pay a premium on every drive. The offload that survives is the one whose value comes from data that is never moved, not from arithmetic performed more cheaply.
Qualification cost is a further limit on the pace of adoption. An enterprise buyer tests a new drive for twelve to eighteen months before it enters a fleet, and a computational storage drive adds firmware, an interface and a security surface to that test. A device that executes customer code inside the storage boundary also raises questions that a plain drive does not, and those questions are answered by security teams rather than by storage teams. There is a downside case that buyers should plan for. If flash prices stay high through 2027, procurement will concentrate on capacity per dollar, feature qualification will be deferred, and revenue now forecast for 2028 and 2029 would move later in the period. These factors substantially limit Computational Storage market growth over the forecast period.
AI inference and vector search grows fastest of the five applications, at a CAGR of 36.0% through 2035 from a 14.5% share of 2025 revenue. Inference systems hold vector indexes and key-value caches that exceed the memory attached to the accelerator, so both are placed on flash and read during the query. Work done on the device, which covers filtering, decompression and approximate nearest-neighbour search, reduces what has to cross the interconnect before the model sees it. For instance, in December 2025, Kioxia, Japan, integrated its AiSAQ technology into the Milvus vector database, which makes an on-flash index reachable from software that developers already run.
Database and analytics acceleration represented 21.8% of 2025 revenue, and its rate through 2035 is put at 22.5%. Pushing a filter or a scan down to the device returns matching records instead of whole blocks, which is valuable for table scans over large columnar datasets. Adoption depends on the query planner, and planners change slowly, so this segment advances with database releases rather than with hardware cycles.
Encryption and data protection, at 17.2% of 2025 revenue, should advance at 21.0% a year through 2035. Encryption at rest and erasure-coding parity are both byte-for-byte functions that map well onto fixed hardware, and regulated industries buy them for audit reasons as well as for throughput. Media processing and others, which covers video transcoding and image pre-processing near storage, accounted for 8.5% of revenue in 2025 and should grow at a CAGR of 15.4% through 2035, since dedicated video processing cards already serve most of that demand from outside the storage device.
Storage vendors headquartered in the region are selling array-level compute into that build. Everpure, the company formerly trading as Pure Storage, reported a design win with a second top-five hyperscaler in August 2026 and joined the S&P 500 in September 2026. Merchant suppliers of drives and accelerator cards are concentrated here as well. ScaleFlux is based in Milpitas, California, and Eideticom, which builds computational storage processors for compression and cryptographic work, lists AMD, Intel, Altera and Los Alamos National Laboratory among its partners. Federal research buyers matter more in this region than elsewhere, because national laboratories will fund the software integration that a commercial buyer will not.
Trade statistics from the region's exporters show where the underlying hardware is made. Semiconductor shipments out of South Korea came to USD 192.4 billion in the first half of 2026, 162.6% above the first half of 2025, on Ministry of Trade, Industry and Resources figures. Information and communication products exported from Taiwan were worth USD 251.2 billion in 2025, an increase of 89.5% on the Ministry of Finance count, with servers and storage bound mainly for United States data centers. India is a later entrant with a smaller installed base. Domestic electronics production there came to INR 13.11 lakh crore in FY2025-26 on Ministry of Electronics and Information Technology figures, against INR 11.3 lakh crore the year before, and new data center capacity is specified with high-capacity flash from the start. DapuStor is the clearest example of a regional supplier building the function into a standard enterprise range rather than selling it as a separate product line.
Regulation is a second influence, and it works in favour of the array-level product. The Data Act entered into force on 11 January 2024 and has applied since 12 September 2025, obliging providers of data processing services to let customers switch between them. Operators responding to that obligation are rebuilding their data movement and format conversion paths, and compute placed in the storage system is one way of performing a conversion without routing the data through a server first. Germany, France, the Netherlands and the Nordic countries hold most of the regional capacity. Public research computing adds a smaller layer of demand that adopts earlier, since research centres will modify their own software stacks to reach a device-side function.
The U.S.-Iran conflict is the principal uncertainty attached to those plans. A downgrade followed in July 2026: the IMF set Middle East growth for the year at 0.7%, 1.2 percentage points lower than its previous figure, attributing the revision to the February blockade of the Strait of Hormuz. Hull war-risk premiums for Gulf callers, under 1% of hull value before the conflict began, now sit anywhere between 1% and 10%. Equipment for these campuses is imported, so higher freight and insurance costs raise the delivered cost of every rack. The likely effect is timing rather than cancellation, with part of the planned purchasing moving into 2028 and beyond.